IEC 60529 Protection Rating
IP51 Rating
IP51 provides level 5 protection against solids and level 1 protection against liquids, as defined by IEC 60529.
5First digit: Solid protection
Dust-protected. Limited ingress of dust permitted, not enough to interfere with operation
Test
Dust chamber, talcum powder
8 hours in dust chamber with pressure differential; no harmful deposits
1Second digit: Liquid protection
Protection against vertically falling water drops (condensation)
Test method
Drip box or oscillating tube
1 mm/min rainfall for 10 minutes
How IP51 compares
| Rating | Solids | Liquids |
|---|---|---|
| IP50 | Dust-protected. Limited ingress of dust permitted, not enough to interfere with operation | No protection against water |
| IP51 | Dust-protected. Limited ingress of dust permitted, not enough to interfere with operation | Protection against vertically falling water drops (condensation) |
| IP52 | Dust-protected. Limited ingress of dust permitted, not enough to interfere with operation | Protection against vertically falling water drops when enclosure is tilted up to 15 degrees |
Validate IP ratings across your catalog